UL Teflon Wire and Cable
UL Teflon Wire and Cable
MOQ : piece
Lead Time : Days
Seller Support : Trade Authenticity Guaranteed & Accepting
Payment : L/C,T/T,Western Union, Money Gram, Credit Card, Paypal
Product details
Supply Ability
- Warranty(Year):1 Year
Product Specifications
Product Description
○Rated Temperature:105-200℃ ○Environment: EU ROHS
○Rated Voltage: 300-600V ○Test Voltage: 3000-3000V
○Insulated Conductors: Any UL or cUL approved conductors
○Color:Black-White-Blue-Brown-Yellow-Green-Red-Transparence
-Yellow & Green (Or Meet the client’s comment)
○Use:Internal wiring of electrical and electronic.
Single-conductor thermoplastic insulation section 2
Rated Temperature | 105℃ | 150℃ | 200℃ | |||||||
Rated Voltage | 300V | 600V | 300V | 600V | ||||||
Style No. | 20311 | 20500 | 20145 | 20712 | 20262 | 20604 | 20711 | 20146 | 20710 | 20723 |
CONDUCTOR(AWG) | 32-20 | ≥32 | ≥24 | --- | --- | --- | --- | ≥24 | --- | 16-4/0 |
Number | 2-255 | ≥2 | 2,3 | ≥2 | 2-7 | 2-6 | ≥2 | 2,3 | ≥2 | ≥2 |
UL Type or style no. | APP | APP | APP | APP | 1332 | APP | APP | APP | APP | APP |
Insulation | Insulation (mm) | |||||||||
Material | FEP | FEP | FEP | FEP | FEP | FEP | FEP | FEP | FEP | FEP |
Thickness Average. | 0.33 | 0.33 | 0.33 | 0.33 | 0.33 | 0.33 | 0.33 | 0.33 | 0.33 | 0.508 |
Thickness Min. | 0.28 | 0.28 | 0.28 | 0.28 | 0.30 | 0.28 | 0.28 | 0.28 | 0.28 | 0.41 |
Multi-assembly | --- | YES | --- | YES | --- | YES | YES | --- | --- | YES |
SEPARATOR(S) | --- | OPT | --- | --- | --- | --- | OPT | --- | OPT | --- |
COVERING | OPT | --- | OPT | --- | --- | --- | --- | OPT | --- | --- |
SHIELDING | --- | OPT | --- | OPT | OPT | OPT | OPT | --- | OPT | --- |
JACKET | Jacket thickness (mm) | |||||||||
Material | --- | FEP | FEP | FEP | FEP | FEP | FEP | FEP | FEP | FEP |
Thickness Average. | --- | 0.30 | 0.508 | 0.30 | 0.508 | 0.28 | 0.254 | 0.508 | 0.30 | 0.38 |
Thickness Min. | --- | 0.254 | 0.46 | 0.254 | 0.46 | 0.23 | 0.203 | 0.46 | 0.254 | 0.33 |
●OPT : Optional.。
●≥2:Not limit to the number of conductors, the only limit being the outer diameter of the complete cable in certain case.
●APP:Each of the conductors used in the cable may have a different cross-section and style number from the others. Each conductor must be approved for a voltage and temperature that is higher than or equal to the values specified for the complete cable.
※Please contact our factory for sizes or information not listed.